Criterion 5.1

The Safety Report should show a clear link between the measures taken and the major accident hazards described.

Relevant Technical Measures Documents

Control Systems[17]

Criterion 5.2

The Safety Report should demonstrate how the measures taken will prevent foreseeable failures, which could lead to major accidents.

Relevant Technical Measures Documents

Control Systems[18]

Criterion 5.2 has been subdivided into lower level criteria, and has been grouped, and can be found on the following pages

Criterion 5.2.1 - Design

This includes the following Criteria:

  • Criterion 5.2.1.1
    The Safety Report should show that the establishment and installations have been designed to an appropriate standard.
  • Criterion 5.2.1.2
    The Safety Report should show that a hierarchical approach to the selection of measures has been used.
  • Criterion 5.2.1.3
    Layout of the plant should limit the risk during operations, inspection, testing, maintenance, modification, repair and replacement.
  • Criterion 5.2.1.4
    Utilities that are needed to implement any measure defined in the safety report should have suitable reliability, availability and survivability.
  • Criterion 5.2.1.5
    The Safety Report should show that appropriate measures have been taken to prevent and effectively contain releases of dangerous substances.
  • Criterion 5.2.1.6
    The Safety Report should show that all foreseeable direct causes of major accidents have been taken into account in the design of the installation.
  • Criterion 5.2.1.7
    The Safety Report should show how structures important to safety have been designed to provide adequate integrity.
  • Criterion 5.2.1.8
    The Safety Report should show how the containment structure has been designed to withstand the loads experienced during normal operation of the plant and all foreseeable operational extremes during its expected life.
  • Criterion 5.2.1.9
    The Safety Report should show that materials of construction used in the plant are suitable for the application.
  • Criterion 5.2.1.10
    The Safety Report should show that adequate safeguards have been provided to protect the plant against excursions beyond design conditions.
  • Criterion 5.1.2.11
    The Safety Report should describe how safety-related control systems have been designed to ensure safety and reliability.
  • Criterion 5.2.1.12
    The Safety Report should show how design systems, which require human interaction have been designed to take into account the needs of the user and be reliable.
  • Criterion 5.2.1.13
    The Safety Report should describe the systems for identifying locations where flammable substances could be present and how the equipment has been designed to take account of the risk.

Criterion 5.2.1.1 webpage

The Safety Report should show that the establishment and installations have been designed to an appropriate standard.

Relevant Technical Measures Documents

Relevant Documentation and Case Studies for Criterion 5.2.1.1

Topic Documents

Design for Containment

Documentation[21]

  • EH70 The control of fire-water run-off from CIMAH sites to prevent environmental damage
  • HS (G) 28 Safety advice for bulk chlorine installations
  • HS (G) 176 The storage of flammable liquids in tanks

Case Studies

Design for redundancy

Documentation[24]

  • IEC 61508 Functional safety of electrical/electronic/programmable electronic safety-related systems
  • HS (G) 28 Safety advice for bulk chlorine installations

Case Studies

Chemstar Ltd Explosion/Fire (06/09/1981)[25]

Segregation

Documentation[26]

  • HS (G) 71 Chemical Warehousing: the storage of packaged dangerous substances
  • HS (G) 176 The storage of flammable liquids in tanks
  • LPGA COP 1 Bulk LPG storage at fixed installations. Part 1: Design, installation and operation of vessels located above ground

Case Studies

Criterion 5.2.1.2 webpage

The Safety Report should show that a hierarchical approach to the selection of measures has been used.

Relevant Technical Measures Documents

Control Systems[29]

Relevant Documentation for Criterion 5.2.1.2

Topic Documents

Inherent Safety

Documentation[30]

  • HS (G) 28 Safety advice for bulk chlorine installations
  • HS (G) 30 Storage of anhydrous ammonia under pressure in the UK: spherical and cylindrical vessels
  • HS (G) 140 Safe use and handling of flammable liquids
  • HS (G) 176 The storage of flammable liquids in tanks
  • HS (G) 190 Preparing safety reports: Control of Major Accident Hazards Regulations 1999
  • LPGA COP 1 Bulk LPG storage at fixed installations. Part 1: Design, installation and operation of vessels located above ground

Criterion 5.2.1.3 webpage

Layout of the plant should limit the risk during operations, inspection, testing, maintenance, modification, repair and replacement.

Relevant Technical Measures Documents

Relevant Documentation and Case Studies for Criterion 5.2.1.3

Layout

Documentation[42]

  • API RP 752 Management of hazards associated with location of process plant buildings
  • BS 5908: 1990 Code of practice for fire precautions in the chemical and allied industries
  • CIA Guidance for the location and design of occupied building on chemical manufacturing sites
  • HS (G) 28 Safety advice for bulk chlorine installations
  • HS (G) 30 Storage of anhydrous ammonia under pressure in the UK: spherical and cylindrical vessels
  • HS (G) 176 The storage of flammable liquids in tanks
  • IGE SR 14 High pressure gas storage: Part 1 - Above ground storage vessels
  • LPGA COP 1 Bulk LPG storage at fixed installations.

Case Studies

Criterion 5.2.1.4 webpage

Utilities that are needed to implement any measure defined in the safety report should have suitable reliability, availability and survivability.

Relevant Technical Measures Documents

Relevant Documentation and Case Studies for Criterion 5.2.1.4

Topic Documents

Utilities

Documentation[49]

  • BS 5908:1990 Code of practice for fire precautions in the chemical and allied industries
  • HS (G) 28 Safety advice for bulk chlorine installations
  • HS (G) 39 Compressed air safety
  • HS (G) 103 Safe handling of combustible dusts: precaution against explosions

Case Studies

Chemstar Ltd Explosion/Fire (06/09/1981)[50]

Criterion 5.2.1.5 webpage

The Safety Report should show that appropriate measures have been taken to prevent and effectively contain releases of dangerous substances.

Relevant Technical Measures Documents

Relevant Documentation and Case Studies for Criterion 5.2.1.5

Topic Documents

Containment Control

Documentation[60]

  • ASME BS 31.3 Process piping: 1999
  • BS 7777:1993 Flat-bottomed, vertical, cylindrical storage tanks for low temperature service
  • EEMUA 147 Recommendations for the design and construction of refrigerated liquefied gas storage tanks
  • HS (G) 28 Safety advice for bulk chlorine installations
  • HS (G) 176 The storage of flammable liquids in tanks
  • HS (G) 186 The bulk transfer of dangerous liquids and gases between ship and shore
  • EH70 The control of fire-water run-off from CIMAH sites to prevent environmental damage

Case Studies

Venting

Documentation[64]

  • API Std 2000 Venting atmospheric and low pressure storage tanks: Non refrigerated and refrigerated
  • BS 2915:1990 Specification for bursting discs and bursting disc devices
  • HS (G) 158 Flame arresters: preventing the spread of fires and explosions in equipment that contains flammable gases and vapours
  • LPGA COP 1 Bulk LPG storage at fixed installations Part 1: Design, installation and operation of vessels located above ground

Case Studies

Polymerisation Runaway Reaction (May 1992)[65]

Isolation

Documentation[66]

  • HS (G) 28 Safety advice for bulk chlorine installations
  • HS (G) 30 Storage of anhydrous ammonia under pressure in the UK: spherical and cylindrical vessels
  • Liquefied petroleum gas. IP Model code of safe practice: Part 9
  • OIAC. Guidance on Permit to Work systems in the petroleum industry

Case Studies

Detection of Releases

Documentation[70]

  • API Std 650 Welded steel tanks for oil storage
  • CS1 Industrial use of flammable gas detectors
  • Ethylene oxide: CIA Guidelines for bulk handling
  • HS (G) 186 The bulk transfer of dangerous liquids and gases between ship and shore
  • IGE SR15 Programmable equipment in safety related applications

Case Studies

Abbeystead Explosion (23/05/1984)[71]

Criterion 5.2.1.6 webpage

The Safety Report should show that all foreseeable direct causes of major accidents have been taken into account in the design of the installation.

Relevant Technical Measures Documents

Relevant Documentation and Case Studies for Criterion 5.2.1.6

Topic Documents

Corrosion / erosion

Documentation[88]

  • API 570 Piping inspection code: Inspection, repair, alteration and rerating of in-service piping systems
  • API RP 572 Inspection of pressure vessels
  • API Std 620 Design and construction of large, welded, low-pressure storage tanks
  • EEMU 159. Users guide to the maintenance and inspection of above ground vertical cylindrical steel storage tanks
  • HS (G) 40 Safe handling of chlorine from drums and cylinders
  • LPGA COP 1 Bulk LPG storage at fixed installations. Part 4: Buried / mounded LPG storage vessels

Case Studies

Staveley Chemicals Ltd Derbyshire (27/06/1982)[89]

Extreme weather

Documentation[90]

  • BS6399: Loading for Buildings
  • BS 7777: 1993 Part 3 Flat-bottomed, vertical, cylindrical storage tanks for low temperature service
  • CS 18 Storage and handling of ammonium nitrate
  • EEMUA 147. Recommendations for the design and construction of refrigerated liquefied gas storage tanks
  • HS (G) 176 The storage of flammable liquid in tanks
  • PM 75 Glass reinforced plastic vessels and tanks: Advice to users

Case Studies

Havkong Incident (23/01/1993)[91]

Impact

Documentation[92]

  • BCGA GN 2 Guidance for the storage of transportable gas cylinders for industrial use
  • EEMUA 147. Recommendations for the design and construction of refrigerated liquefied gas storage tanks
  • PM 75 Glass reinforced plastic vessels and tanks: Advice to users

Case Studies

Allied Colloids Limited (21/07/1992)[93]

Overpressure

Documentation[94]

  • API RP 520 Sizing, selection, and installation of pressure relieving devices in refineries
  • API RP 521 Guide for the pressure-relieving and depressurising systems
  • API Std 2000 Venting atmospheric and low pressure storage tanks: Non refrigerated and refrigerated
  • BS 2915:1990 Specification for bursting discs and bursting disc devices
  • BS 6759 Safety valves
  • CRR 136 Workbook for chemical relief system sizing
  • EEMU 184 Guide to the isolation of pressure relieving devices
  • HS (G) 176 The storage of flammable liquids in tanks

Case Studies

Inspection

Documentation[98]

  • API 570 Piping inspection code: Inspection, repair, alteration and rerating of in-service piping systems
  • API RP 572 Inspection of pressure vessels
  • ASME Boiler and pressure vessel code: 1998
  • BS 7777:1993 Flat bottomed, vertical, cylindrical storage tanks for low temperature service
  • EEMUA 159. Users guide to the maintenance and inspection of above-ground vertical cylindrical steel storage tanks
  • LPGA COP 1 Bulk LPG storage at fixed installations. Part 3: Periodic inspection and testing
  • LPGA COP 1 Bulk LPG storage at fixed installations. Part 4: Buried / mounded LPG storage vessels
  • PM 75 Glass reinforced plastic vessels and tanks: Advice to users

Fire walls

Documentation[99]

  • LPGA COP 7 Storage of full and empty LPG cylinders and cartridges
  • NFPA 221 Standard for fire walls and fire barrier walls

Insulation

Documentation[100]

  • BS 5908:1990 Code of practice for fire precautions in the chemical and allied industries
  • EEMUA 147 Recommendations for the design and construction of refrigerated liquefied gas storage tanks
  • Ethylene oxide: CIA Guidelines for bulk handling

Case Studies

Feyzin (04/01/1966)[101]

Vibration

Documentation[102]

  • ASME Boiler and pressure vessel code: 1998

Human error

Documentation[103]

  • API Std 2000 Venting atmospheric and low pressure storage tanks: Non refrigerated and refrigerated
  • IChemE An engineer's view of human error
  • HS (G) 48 Reducing error and influencing behaviour
  • HS (G) 65 Successful health and safety management

Case Studies

Criterion 5.2.1.7 webpage

The Safety Report should show how structures important to safety have been designed to provide adequate integrity.

Relevant Technical Measures Document

Relevant Documentation and Case Studies for Criterion 5.2.1.7

Topic Documents

Safety of structures

Documentation[109]

  • BS 6399 Loading for buildings
  • BS 6651:1999 Code of practice for protection of structures against lightning
  • BS 7777:1993 Part3 Flat bottomed, vertical, cylindrical storage tanks for low temperature service
  • CS 18 Storage and handling of ammonium nitrate
  • EEMUA 147. Recommendations for the design and construction of refrigerated liquefied gas storage tanks
  • HS (G) 71 Chemical warehousing: the storage of packaged dangerous substances
  • HS (G) 176 The storage of flammable liquids in tanks

Case Studies

Flixborough (Nypro UK) Explosion (01/06/1974)[110]

Criterion 5.2.1.8 webpage

The Safety Report should show how the containment structure has been designed to withstand the loads experienced during normal operation of the plant and all foreseeable operational extremes during its expected life.

Relevant Technical Measures Documents

Relevant Documentation for Criterion 5.2.1.8

Topic Documents

Design margins

Documentation[114]

  • API Std 620 Design and construction of large, welded, low pressure storage tanks
  • BS 6759 Safety valves
  • HS (G) 176 The storage of flammable liquids in tanks
  • IGE SR 14 High pressure gas storage: Part 1 - Above ground storage vessels
  • LPGA COP 22 LPG piping system design and installation

Criterion 5.2.1.9 webpage

The Safety Report should show that materials of construction used in the plant are suitable for the application.

Relevant Technical Measures Documents

Relevant Documentation for Criterion 5.2.1.9

Topic Documents

Materials of construction

Documentation[119]

  • BS 2594:1975 Specification for carbon steel welded horizontal cylindrical storage tanks
  • EEMUA 147. Recommendations for the design and construction of refrigerated liquefied gas storage tanks
  • HS (G) 158 Flame arresters: preventing the spread of fires and explosions in equipment that contains flammable gases and vapours
  • HS (G) 176 The storage of flammable liquids in tanks
  • PD 5500: 2003 Specification for unfired fusion welded pressure vessels
  • PM 75 Glass reinforced plastic vessels and tanks: Advice to users
  • SIR 19 Fire and explosion hazards associated with the storage and handling of hydrogen peroxide

Criterion 5.2.1.10 webpage

The Safety Report should show that adequate safeguards have been provided to protect the plant against excursions beyond design conditions.

Relevant Technical Measures Documents

Relevant Documentation and Case Studies for Criterion 5.2.1.10

Topic Documents

Safe operating limits

Documentation[126]

  • HS (G) 93 The assessment of pressure vessels operating at low temperature
  • IGE SR 14 High pressure gas storage: Part 1 - Above ground storage vessels
  • L 122 Safety of Pressure Systems - Pressure Systems Safety Regulations 2000

Case Studies

Chemstar Ltd Explosion/Fire (06/09/1981)[127]

Control Systems[128]

Documentation[129]

  • CRR 166 The management of alarm systems
  • EEMUA 160. Safety related instrument systems for the process industries
  • EEMUA 184 Guide to the isolation of pressure relieving devices
  • IEC 61508 Functional safety of electrical / electronic/ programmable electronic safety-related systems

Case Studies

Criterion 5.2.1.11

The Safety Report should describe how safety-related control systems have been designed to ensure safety and reliability.

Relevant Technical Measures Documents

Relevant Documentation for Criterion 5.2.1.11

Topic Documents

Safety related control

Documentation[139]

  • IEC 61508 Functional safety of electrical / electronic programmable electronic safety-related systems
  • EEMUA 160. Safety related instrument systems for the process industries
  • IGE SR 15 Programmable equipment in safety related applications

Criterion 5.2.1.12 webpage

The Safety Report should show how design systems, which require human interaction have been designed to take into account the needs of the user and be reliable.

Relevant Technical Measures Documents

Relevant Documentation and Case Studies for Criterion 5.2.1.12

Topic Documents

Human factors

Documentation[148]

  • CRR 166 The management of alarm systems
  • IChemE An engineers view of human error
  • HS (G) 48 Reducing error and influencing behaviour
  • HS (G) 65 Successful health and safety management

Case Studies

Criterion 5.2.1.13 webpage

The Safety Report should describe the systems for identifying locations where flammable substances could be present and how the equipment has been designed to take account of the risk.

Relevant Technical Measures Documents

Relevant Documentation and Case Studies for Criterion 5.2.1.13

Topic Documents

Control of hazardous areas

Documentation[154]

  • BS 6656: 2002 Guide to prevention of inadvertent ignition of flammable atmospheres by radio-frequency radiation
  • BS EN 50014: 1998 Electrical apparatus for potentially explosive atmospheres. General requirements
  • BS EN 60079-10: 2003 Electrical apparatus for explosive gas atmospheres. Classification of hazardous areas
  • HS (G) 103 Safe handling of combustible dusts: precautions against explosions
  • HS (G) 113 Lift trucks in potentially flammable atmospheres
  • HS (G) 140 Safe use and handling of flammable liquids
  • HS (G) 176 The storage of flammable liquids in tanks
  • HS (G) 186 The bulk transfer of dangerous liquids and gases between ship and shore
  • RC 20 Recommendations for the storage and use of flammable liquids

Case Studies

5.2.2 - Construction

This includes the following Criteria:

  • Criterion 5.2.2.1
    The Safety Report should show that the installations have been constructed to appropriate standards to prevent major accidents and reduce loss of containment.
  • Criterion 5.2.2.2
    The Safety Report should describe how the construction of all plant and systems is assessed and verified against the appropriate standards to ensure adequate safety.

Criterion 5.2.2.1 webpage[157]

The Safety Report should show that the installations have been constructed to appropriate standards to prevent major accidents and reduce loss of containment.

Relevant Technical Measures Documents

Relevant Documentation for Criterion 5.2.2.1

Topic Documents

Initial testing of constructed plant

Documentation[161]

  • ASME Boiler and pressure vessel code: 1998
  • ASME B 31.3 Process piping: 1999
  • BS EN 288 Specification and approval of welded procedures for metallic materials
  • BS 5306 Fire extinguishing installations and equipment on premises
  • BS 6759 Safety valves
  • BS 7430: 1998 Code of practice for earthing
  • BS 7777: 1993 Flat bottomed, vertical, cylindrical storage tanks for low temperature service
  • CRR 166 The management of alarm systems
  • EEMUA 147 Recommendations for the design and construction of refrigerated liquefied gas storage tanks
  • GS 4 Safety in pressure testing
  • PD 5500: 2000 Specification for unfired fusion welded pressure vessels
  • PM 75 Glass reinforced plastic vessels and tanks: Advice to users

Criterion 5.2.2.2 webpage

The Safety Report should describe how the construction of all plant and systems is assessed and verified against the appropriate standards to ensure adequate safety.

Relevant Technical Measures Documents

Relevant Documentation and Case Studies for Criterion 5.2.2.2

Verification of construction

Documentation[165]

  • CRR 166 The management of alarm systems
  • EEMU 160. Safety related instrument systems for the process industries
  • LPGA COP Bulk LPG storage at fixed installations: Part 3: Periodic inspection and testing

Case Studies

Flixborough (Nypro UK) Explosion (01/06/1974)[166]

5.2.3 - Operation

This includes the following Criteria:

Criterion 5.2.3.1

The Safety Report should show that safe operating procedures have been established and are documented for all reasonably foreseeable condition.

Relevant Technical Measures Documents

Relevant Documentation and Case Studies for Criterion 5.2.3.1

Topic Documents

Safe operating procedures

Documentation[169]

  • BS 5908: 1990 Code of practice for fire precautions in the chemical and allied industries
  • HS (G) 65 Successful health and safety management

Case Studies

Seveso - Icmesa Chemical Company (09/07/1976)[170]

5.2.4 - Maintenance

This includes the following Criteria:

  • Criterion 5.2.4.1
    The Safety Report should show that an appropriate maintenance scheme is established for plant and systems to prevent major accidents or reduce the loss of containment in the event of such accidents.
  • Criterion 5.2.4.2
    The Safety Report should show that there are appropriate procedures for maintenance that take account of any hazardous conditions within the working environment.
  • Criterion 5.2.4.3
    The Safety Reports should show that systems are in place to ensure that safety critical plant and systems are examined at appropriate intervals by a competent person.
  • Criterion 5.2.4.4
    The Safety Report should show that there is a system in place to ensure the continued safety of the installations based on the results of periodic examinations and maintenance.

Criterion 5.2.4.1 webpage

The Safety Report should show that an appropriate maintenance scheme is established for plant and systems to prevent major accidents or reduce the loss of containment in the event of such accidents.

Relevant Technical Measures Documents

Relevant Documentation and Case Studies for Criterion 5.2.4.1

Topic Documents

Maintenance

Documentation[176]

  • HS (G) 28 Safety advice for bulk chlorine installations
  • HS (G) 176 The storage of flammable liquids in tanks
  • LPGA COP 1 Bulk storage Tat fixed installations. Part 3: Periodic inspection and testing

Case Studies

Proof testing

Documentation[179]

  • ASME Boiler and pressure vessel code: 1998
  • EEMUA 147. Recommendations for the design and construction of refrigerated liquefied gas storage tanks
  • IEC 61508 Functional safety of electrical/electronic/programmable electronic safety related systems
  • LPGA COP 22 LPG piping system design and installation

Case Studies

Polymerisation Runaway Reaction (May 1992)[180]

Criterion 5.2.4.2 webpage

The Safety Report should show that there are appropriate procedures for maintenance that take account of any hazardous conditions within the working environment.

Relevant Technical Measures Documents

Relevant Documentation and Case Studies for Criterion 5.2.4.2

Topic Documents

Permit to work

Documentation[184]

  • HS (G) 5 Hot work: welding and cutting on plant containing flammable materials
  • HS (G) 64 Assessment of fire hazards from solid materials and the precautions required for their safe storage and use
  • HS (G) 65 Successful health and safety management
  • HS (G) 140 Safe use and handling of flammable liquids
  • OIAC. Guidance on permit-to-work systems in the petroleum industry

Case Studies

Hickson and Welch Ltd Fire (22/09/1992)[185]

Maintenance Procedures

Documentation[186]

  • EEMUA 186. A practitioners handbook - Electrical installation and maintenance in potentially explosive atmospheres
  • GS 4 Safety in pressure testing
  • HS (G) 65 Successful health and safety management
  • OIAC. The safe isolation of plant and equipment

Criterion 5.2.4.3 webpage

The Safety Reports should show that systems are in place to ensure that safety critical plant and systems are examined at appropriate intervals by a competent person.

Relevant Technical Measures Documents

Relevant Documentation for Criterion 5.2.4.3

Topic Documents

Competent person

Documentation[189]

  • API 570 Piping inspection code: Inspection, repair, alteration and rerating of in service piping systems
  • API RP 572 Inspection of pressure vessels
  • ASME Boiler and pressure vessel code: 1998
  • BS 7777: 1993 Flat bottomed, vertical, cylindrical storage tanks for low temperature service
  • EEMUA 159. Users' guide to the maintenance and inspection of above-ground vertical cylindrical steel storage tanks
  • LPGA COP 1 Bulk LPG storage at fixed installations. Part 3: Periodic inspection and testing
  • LPGA COP 1 Bulk LPG storage at fixed installations. Part 4: Buried / mounded LPG storage vessels
  • PM 75 Glass reinforced plastic vessels and tanks: Advice to users

Criterion 5.2.4.4

The Safety Report should show that there is a system in place to ensure the continued safety of the installations based on the results of periodic examinations and maintenance.

Relevant Technical Measures Documents

Relevant Documentation and Case Studies for Criterion 5.2.4.4

Topic Documents

Plant modifications

Documentation[192]

  • HS (G) 28 Safety advice for bulk chlorine installations
  • HS (G) 30 Storage of anhydrous ammonia under pressure in the UK: spherical and cylindrical vessels
  • HS (G) 65 Successful health and safety management
  • HS (G) 176 The storage of flammable liquids in tanks

Case Studies

5.2.5 - Modification

This includes the following Criteria:

Criterion 5.2.5.1

The Safety Report should describe the system in place for ensuring modifications are adequately conceived, designed, installed and tested.

Relevant Technical Measures Documents

Plant Modification / Change Procedures[195]

Relevant Documentation for Criterion 5.2.5.1

Change procedures

Documentation[196]

  • CIA Guide to Hazard and Operability Studies, CISHEC/8906/1000
  • HS (G) 65 Successful health and safety management

Link URLs in this page

  1. COMAHhttps://www.hse.gov.uk/comah/index.htm
  2. Overview - Backgroundhttps://www.hse.gov.uk/comah/background/index.htm
  3. Seveso IIIhttps://www.hse.gov.uk/seveso/index.htm
  4. COMAH Regulations 2015https://www.hse.gov.uk/comah/background/comah15.htm
  5. Cost recovery in detailhttps://www.hse.gov.uk/comah/charging/index.htm
  6. The COMAH Competent Authorityhttps://www.hse.gov.uk/comah/authorityindex.htm
  7. Guidancehttps://www.hse.gov.uk/comah/guidance.htm
  8. Competent authority guidance and key internal CA procedureshttps://www.hse.gov.uk/comah/ca-guides.htm
  9. Notificationshttps://www.hse.gov.uk/comah/notification/index.htm
  10. Submitting public informationhttps://www.hse.gov.uk/comah/submitting-public-information.htm
  11. Establishments subject to COMAH 2015https://www.hse.gov.uk/comah/comah-establishments.htm
  12. Emergency plan testing during coronavirushttps://www.hse.gov.uk/comah/external-emergency-plan-tests-during-coronavirus.htm
  13. Resourceshttps://www.hse.gov.uk/comah/resources.htm
  14. Safety alertshttps://www.hse.gov.uk/comah/alerts/index.htm
  15. Investigation reportshttps://www.hse.gov.uk/comah/investigation-reports.htm
  16. Complete a short surveyhttps://www.surveymonkey.com/r/3YY388L
  17. Control Systemshttps://www.hse.gov.uk/comah/sragtech/techmeascontsyst.htm
  18. Control Systemshttps://www.hse.gov.uk/comah/sragtech/techmeascontsyst.htm
  19. Control Systemshttps://www.hse.gov.uk/comah/sragtech/techmeascontsyst.htm
  20. Drum / Cylinder Handlinghttps://www.hse.gov.uk/comah/sragtech/techmeascylinder.htm
  21. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  22. Chicago Gas Release (26/04/1974)https://www.hse.gov.uk/comah/sragtech/casechicago74.htm
  23. Seveso - Icmesa Chemical Company (09/07/1976)https://www.hse.gov.uk/comah/sragtech/caseseveso76.htm
  24. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  25. Chemstar Ltd Explosion/Fire (06/09/1981)https://www.hse.gov.uk/comah/sragtech/casechemstar81.htm
  26. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  27. Allied Colloids Limited (21/07/1992)https://www.hse.gov.uk/comah/sragtech/casealliedcol92.htm
  28. Staveley Chemicals Ltd Derbyshire (27/06/1982)https://www.hse.gov.uk/comah/sragtech/casestaveley82.htm
  29. Control Systemshttps://www.hse.gov.uk/comah/sragtech/techmeascontsyst.htm
  30. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  31. Control Systemshttps://www.hse.gov.uk/comah/sragtech/techmeascontsyst.htm
  32. Design Codes - Buildings / Structureshttps://www.hse.gov.uk/comah/sragtech/techmeasbuilding.htm
  33. Emergency Response / Spill Controlhttps://www.hse.gov.uk/comah/sragtech/techmeasspill.htm
  34. Explosion Reliefhttps://www.hse.gov.uk/comah/sragtech/techmeasexplosio.htm
  35. Hazardous Area Classification / Flameproofinghttps://www.hse.gov.uk/comah/sragtech/techmeasareaclas.htm
  36. Inspection / Non-Destructive Testing (NDT)https://www.hse.gov.uk/comah/sragtech/techmeasndt.htm
  37. Maintenance Procedureshttps://www.hse.gov.uk/comah/sragtech/techmeasmaintena.htm
  38. Plant Layouthttps://www.hse.gov.uk/comah/sragtech/techmeasplantlay.htm
  39. Quench Systemshttps://www.hse.gov.uk/comah/sragtech/techmeasquench.htm
  40. Relief Systems / Vent Systemshttps://www.hse.gov.uk/comah/sragtech/techmeasventsyst.htm
  41. Segregation of Hazardous Materialshttps://www.hse.gov.uk/comah/sragtech/techmeassegregat.htm
  42. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  43. Flixborough (Nypro UK) Explosion (01/06/1974)https://www.hse.gov.uk/comah/sragtech/caseflixboroug74.htm
  44. Mexico City - Pemex LPG Terminal (19/11/1984)https://www.hse.gov.uk/comah/sragtech/casepemex84.htm
  45. Control Systemshttps://www.hse.gov.uk/comah/sragtech/techmeascontsyst.htm
  46. Operating Procedureshttps://www.hse.gov.uk/comah/sragtech/techmeasoperatio.htm
  47. Plant Modification / Change Procedureshttps://www.hse.gov.uk/comah/sragtech/techmeasplantmod.htm
  48. Reliability of Utilitieshttps://www.hse.gov.uk/comah/sragtech/techmeasutilitie.htm
  49. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  50. Chemstar Ltd Explosion/Fire (06/09/1981)https://www.hse.gov.uk/comah/sragtech/casechemstar81.htm
  51. Control Systemshttps://www.hse.gov.uk/comah/sragtech/techmeascontsyst.htm
  52. Design Codes - Pipeworkhttps://www.hse.gov.uk/comah/sragtech/techmeaspipework.htm
  53. Design Codes - Planthttps://www.hse.gov.uk/comah/sragtech/techmeasplant.htm
  54. Emergency Isolationhttps://www.hse.gov.uk/comah/sragtech/techmeasisolatio.htm
  55. Leak / Gas Detectionhttps://www.hse.gov.uk/comah/sragtech/techmeasleakgas.htm
  56. Reaction / Product Testinghttps://www.hse.gov.uk/comah/sragtech/techmeasreaction.htm
  57. Relief Systems / Vent Systemshttps://www.hse.gov.uk/comah/sragtech/techmeasventsyst.htm
  58. Roadways / Site Traffic Control / Immobilisation of Vehicleshttps://www.hse.gov.uk/comah/sragtech/techmeastraffic.htm
  59. Secondary Containmenthttps://www.hse.gov.uk/comah/sragtech/techmeascontain.htm
  60. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  61. Chicago Gas Release (26/04/1974)https://www.hse.gov.uk/comah/sragtech/casechicago74.htm
  62. Feyzin (04/01/1966)https://www.hse.gov.uk/comah/sragtech/casefeyzin66.htm
  63. Seveso - Icmesa Chemical Company (09/07/1976)https://www.hse.gov.uk/comah/sragtech/caseseveso76.htm
  64. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  65. Polymerisation Runaway Reaction (May 1992)https://www.hse.gov.uk/comah/sragtech/casepolymerisa92.htm
  66. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  67. Associated Octel Company Limited (01/02/1994)https://www.hse.gov.uk/comah/sragtech/caseoctel94.htm
  68. BP Oil (Grangemouth) Refinery Ltd (22/03/1987)https://www.hse.gov.uk/comah/sragtech/casebpgrang87b.htm
  69. San Francisco Natural Gas Pipeline Puncture (25/08/1981)https://www.hse.gov.uk/comah/sragtech/casesanfran81.htm
  70. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  71. Abbeystead Explosion (23/05/1984)https://www.hse.gov.uk/comah/sragtech/caseabbeystead84.htm
  72. Active / Passive Fire Protectionhttps://www.hse.gov.uk/comah/sragtech/techmeasfire.htm
  73. Control Systemshttps://www.hse.gov.uk/comah/sragtech/techmeascontsyst.htm
  74. Corrosion / Selection of Materialshttps://www.hse.gov.uk/comah/sragtech/techmeasmaterial.htm
  75. Design Codes - Buildings / Structureshttps://www.hse.gov.uk/comah/sragtech/techmeasbuilding.htm
  76. Design Codes - Pipeworkhttps://www.hse.gov.uk/comah/sragtech/techmeaspipework.htm
  77. Design Codes - Planthttps://www.hse.gov.uk/comah/sragtech/techmeasplant.htm
  78. Explosion Reliefhttps://www.hse.gov.uk/comah/sragtech/techmeasexplosio.htm
  79. Inspection / Non-Destructive Testing (NDT)https://www.hse.gov.uk/comah/sragtech/techmeasndt.htm
  80. Lifting Procedureshttps://www.hse.gov.uk/comah/sragtech/techmeaslifting.htm
  81. Operating Procedureshttps://www.hse.gov.uk/comah/sragtech/techmeasoperatio.htm
  82. Plant Layouthttps://www.hse.gov.uk/comah/sragtech/techmeasplantlay.htm
  83. Plant Modification / Change Procedureshttps://www.hse.gov.uk/comah/sragtech/techmeasplantmod.htm
  84. Relief Systems / Vent Systemshttps://www.hse.gov.uk/comah/sragtech/techmeasventsyst.htm
  85. Roadways / Site Traffic Control / Immobilisation of Vehicleshttps://www.hse.gov.uk/comah/sragtech/techmeastraffic.htm
  86. Reaction / Product Testinghttps://www.hse.gov.uk/comah/sragtech/techmeasreaction.htm
  87. Traininghttps://www.hse.gov.uk/comah/sragtech/techmeastraining.htm
  88. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  89. Staveley Chemicals Ltd Derbyshire (27/06/1982)https://www.hse.gov.uk/comah/sragtech/casestaveley82.htm
  90. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  91. Havkong Incident (23/01/1993)https://www.hse.gov.uk/comah/sragtech/casehavkong93.htm
  92. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  93. Allied Colloids Limited (21/07/1992)https://www.hse.gov.uk/comah/sragtech/casealliedcol92.htm
  94. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  95. International Biosynthetics Ltd (07/12/1991)https://www.hse.gov.uk/comah/sragtech/casebiosynthey91.htm
  96. Chicago Gas Release (26/04/1974)https://www.hse.gov.uk/comah/sragtech/casechicago74.htm
  97. Rupture of a Liquid Nitrogen Storage Tank - Japan (28/08/1992)https://www.hse.gov.uk/comah/sragtech/caseliqnitro92.htm
  98. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  99. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  100. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  101. Feyzin (04/01/1966)https://www.hse.gov.uk/comah/sragtech/casefeyzin66.htm
  102. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  103. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  104. Chemstar Ltd Explosion/Fire (06/09/1981)https://www.hse.gov.uk/comah/sragtech/casechemstar81.htm
  105. San Francisco Natural Gas Pipeline Puncture (25/08/1981)https://www.hse.gov.uk/comah/sragtech/casesanfran81.htm
  106. Control Room Designhttps://www.hse.gov.uk/comah/sragtech/techmeascontrol.htm
  107. Design Codes - Buildings / Structureshttps://www.hse.gov.uk/comah/sragtech/techmeasbuilding.htm
  108. Design Codes - Planthttps://www.hse.gov.uk/comah/sragtech/techmeasplant.htm
  109. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  110. Flixborough (Nypro UK) Explosion (01/06/1974)https://www.hse.gov.uk/comah/sragtech/caseflixboroug74.htm
  111. Control Room Designhttps://www.hse.gov.uk/comah/sragtech/techmeascontrol.htm
  112. Design Codes - Buildings / Structureshttps://www.hse.gov.uk/comah/sragtech/techmeasbuilding.htm
  113. Design Codes - Planthttps://www.hse.gov.uk/comah/sragtech/techmeasplant.htm
  114. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  115. Control Systemshttps://www.hse.gov.uk/comah/sragtech/techmeascontsyst.htm
  116. Corrosion / Selection of Materialshttps://www.hse.gov.uk/comah/sragtech/techmeasmaterial.htm
  117. Raw Materials Control / Samplinghttps://www.hse.gov.uk/comah/sragtech/techmeassampling.htm
  118. Reaction / Product Testinghttps://www.hse.gov.uk/comah/sragtech/techmeasreaction.htm
  119. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  120. Control Systemshttps://www.hse.gov.uk/comah/sragtech/techmeascontsyst.htm
  121. Design Codes - Planthttps://www.hse.gov.uk/comah/sragtech/techmeasplant.htm
  122. Explosion Reliefhttps://www.hse.gov.uk/comah/sragtech/techmeasexplosio.htm
  123. Operating Procedureshttps://www.hse.gov.uk/comah/sragtech/techmeasoperatio.htm
  124. Relief Systems / Vent Systemshttps://www.hse.gov.uk/comah/sragtech/techmeasventsyst.htm
  125. Reliability of Utilitieshttps://www.hse.gov.uk/comah/sragtech/techmeasutilitie.htm
  126. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  127. Chemstar Ltd Explosion/Fire (06/09/1981)https://www.hse.gov.uk/comah/sragtech/casechemstar81.htm
  128. Control Systemshttps://www.hse.gov.uk/comah/sragtech/techmeascontsyst.htm
  129. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  130. Hickson and Welch Ltd Fire (22/09/1992)https://www.hse.gov.uk/comah/sragtech/casehickwel92.htm
  131. Seveso - Icmesa Chemical Company (09/07/1976)https://www.hse.gov.uk/comah/sragtech/caseseveso76.htm
  132. Control Systemshttps://www.hse.gov.uk/comah/sragtech/techmeascontsyst.htm
  133. Earthinghttps://www.hse.gov.uk/comah/sragtech/techmeasearthing.htm
  134. Hazardous Area Classification / Flameproofinghttps://www.hse.gov.uk/comah/sragtech/techmeasareaclas.htm
  135. Inspection / Non-Destructive Testing (NDT)https://www.hse.gov.uk/comah/sragtech/techmeasndt.htm
  136. Emergency Isolationhttps://www.hse.gov.uk/comah/sragtech/techmeasisolatio.htm
  137. Lifting Procedureshttps://www.hse.gov.uk/comah/sragtech/techmeaslifting.htm
  138. Operating Procedureshttps://www.hse.gov.uk/comah/sragtech/techmeasoperatio.htm
  139. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  140. Control Room Designhttps://www.hse.gov.uk/comah/sragtech/techmeascontrol.htm
  141. Control Systemshttps://www.hse.gov.uk/comah/sragtech/techmeascontsyst.htm
  142. Design Codes - Planthttps://www.hse.gov.uk/comah/sragtech/techmeasplant.htm
  143. Lifting Procedureshttps://www.hse.gov.uk/comah/sragtech/techmeaslifting.htm
  144. Operating Procedureshttps://www.hse.gov.uk/comah/sragtech/techmeasoperatio.htm
  145. Permit to Work Systemshttps://www.hse.gov.uk/comah/sragtech/techmeaspermit.htm
  146. Traininghttps://www.hse.gov.uk/comah/sragtech/techmeastraining.htm
  147. Warning Signshttps://www.hse.gov.uk/comah/sragtech/techmeassigns.htm
  148. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  149. Chemstar Ltd Explosion/Fire (06/09/1981)https://www.hse.gov.uk/comah/sragtech/casechemstar81.htm
  150. San Francisco Natural Gas Pipeline Puncture (25/08/1981)https://www.hse.gov.uk/comah/sragtech/casesanfran81.htm
  151. Earthinghttps://www.hse.gov.uk/comah/sragtech/techmeasearthing.htm
  152. Hazardous Area Classification / Flameproofinghttps://www.hse.gov.uk/comah/sragtech/techmeasareaclas.htm
  153. Inertinghttps://www.hse.gov.uk/comah/sragtech/techmeasinerting.htm
  154. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  155. BP Oil - Dalmeny Refinery (11/06/1987)https://www.hse.gov.uk/comah/sragtech/casebpdalment87.htm
  156. Hickson and Welch Ltd Fire (22/09/1992)https://www.hse.gov.uk/comah/sragtech/casehickwel92.htm
  157. Criterion 5.2.2.1 webpagehttps://www.hse.gov.uk/comah/ca-guides.htm#sram
  158. Control Systemshttps://www.hse.gov.uk/comah/sragtech/techmeascontsyst.htm
  159. Design Codes - Planthttps://www.hse.gov.uk/comah/sragtech/techmeasplant.htm
  160. Plant Modification / Change Procedureshttps://www.hse.gov.uk/comah/sragtech/techmeasplantmod.htm
  161. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  162. Control Systemshttps://www.hse.gov.uk/comah/sragtech/techmeascontsyst.htm
  163. Inspection / Non-Destructive Testing (NDT)https://www.hse.gov.uk/comah/sragtech/techmeasndt.htm
  164. Operating Procedureshttps://www.hse.gov.uk/comah/sragtech/techmeasoperatio.htm
  165. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  166. Flixborough (Nypro UK) Explosion (01/06/1974)https://www.hse.gov.uk/comah/sragtech/caseflixboroug74.htm
  167. Control Systemshttps://www.hse.gov.uk/comah/sragtech/techmeascontsyst.htm
  168. Operating Procedureshttps://www.hse.gov.uk/comah/sragtech/techmeasoperatio.htm
  169. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  170. Seveso - Icmesa Chemical Company (09/07/1976)https://www.hse.gov.uk/comah/sragtech/caseseveso76.htm
  171. Control Systemshttps://www.hse.gov.uk/comah/sragtech/techmeascontsyst.htm
  172. Inspection / Non-Destructive Testing (NDT)https://www.hse.gov.uk/comah/sragtech/techmeasndt.htm
  173. Maintenance Procedureshttps://www.hse.gov.uk/comah/sragtech/techmeasmaintena.htm
  174. Permit to Work Systemshttps://www.hse.gov.uk/comah/sragtech/techmeaspermit.htm
  175. Reliability of Utilitieshttps://www.hse.gov.uk/comah/sragtech/techmeasutilitie.htm
  176. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  177. BP Oil (Grangemouth) Refinery Ltd (22/03/1987)https://www.hse.gov.uk/comah/sragtech/casebpgrang87b.htm
  178. Pasadena - Phillips 66 (23/10/1989)https://www.hse.gov.uk/comah/sragtech/casepasadena89.htm
  179. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  180. Polymerisation Runaway Reaction (May 1992)https://www.hse.gov.uk/comah/sragtech/casepolymerisa92.htm
  181. Hazardous Area Classification / Flameproofinghttps://www.hse.gov.uk/comah/sragtech/techmeasareaclas.htm
  182. Maintenance Procedureshttps://www.hse.gov.uk/comah/sragtech/techmeasmaintena.htm
  183. Permit to Work Systemshttps://www.hse.gov.uk/comah/sragtech/techmeaspermit.htm
  184. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  185. Hickson and Welch Ltd Fire (22/09/1992)https://www.hse.gov.uk/comah/sragtech/casehickwel92.htm
  186. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  187. Drum / Cylinder Handlinghttps://www.hse.gov.uk/comah/sragtech/techmeascylinder.htm
  188. Inspection / Non-Destructive Testing (NDT)https://www.hse.gov.uk/comah/sragtech/techmeasndt.htm
  189. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  190. Inspection / Non-Destructive Testing (NDT)https://www.hse.gov.uk/comah/sragtech/techmeasndt.htm
  191. Maintenance Procedureshttps://www.hse.gov.uk/comah/sragtech/techmeasmaintena.htm
  192. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  193. Bhopal - Union Carbide (03/12/1984)https://www.hse.gov.uk/comah/sragtech/caseuncarbide84.htm
  194. Pasadena - Phillips 66 (23/10/1989)https://www.hse.gov.uk/comah/sragtech/casepasadena89.htm
  195. Plant Modification / Change Procedureshttps://www.hse.gov.uk/comah/sragtech/techmeasplantmod.htm
  196. Documentationhttps://www.hse.gov.uk/comah/sragtech/docs.htm
  197. COMAH: Notification formhttps://www.hse.gov.uk/comah/assets/docs/comah-notification-form.xlsx
  198. A guide to the COMAH regulations 2015 (L111) https://www.hse.gov.uk/pubns/books/l111.htm
  199. Leadership for the major hazard industrieshttps://www.hse.gov.uk/pubns/indg277.htm
  200. Better alarm handlinghttps://www.hse.gov.uk/pubns/chis6.pdf
  201. Chemicalshttps://www.hse.gov.uk/chemicals/index.htm
  202. Nuclearhttp://www.onr.org.uk/
  203. Managing human factorshttps://www.hse.gov.uk/humanfactors/index.htm
  204. Safety bulletinshttps://www.hse.gov.uk/safetybulletins/index.htm
  205. Seveso III Directive https://www.hse.gov.uk/seveso/index.htm

Glossary of abbreviations/acronyms on this page